Since 1872   
WE 274B
Performance Graphs & Mechanical Dimensions



Typical Operating Conditions

With Choke-Input Filter:

A-C Plate Voltage per Plate (RMS)...........................550 volts
D-C Output Current......................................160 milliamperes
D-C Output Voltage, Approximate, at Input to Filter......................................................430 volts
Filter Input Choke.......................................................5 henrys
 
 

With Capacitor-Input Filter:

A-C Plate Voltage per Plate (RMS)..........................................................450 volts
D-C Output Current.....................................140 milliamperes
D-C Output Voltage, Approximate, at Input to Filter.....................................................475 volts

Total Effective Plate-Supply

Impedance per Plate.............................................180 ohms
Filter Input Capacitor.........................................4 microfarads


RMS AC Volts / Plate
Total Rectified Current
in Volts
in milliamps
Choke-Input Filter
550 
160 
* 550 
200 
* 660 
160 
Capacitor-Input Filter
450 
140 
* 450 
** 150 
* Max. operating conditions
** 4 mF. max. filter input cap.

A less severe condition should be selected in preference to a maximum operating condition wherever possible. The life of the tube at maximum conditions may be shorter than at less severe conditions.

Double the above listed values of rectified current may be obtained from two tubes by connecting the two plates of each tube together, and using one tube in each side of the circuit.



Outline Drawing of 274B Vacuum Tube


Ordering Information:
Code 274B Electron Tube
Application Full Wave Rectifier
Comcode 100792399

 